Designing devices for load-shedding
Power cuts, dips, inverter switch-overs and whole neighbourhoods coming back at once. A checklist for devices that live on an unreliable grid.
Firmware, Reliability
A device on mains power in a region with an unstable grid sees scheduled load-shedding, voltage dips, inverter and generator switch-overs, and the moment power returns to a whole area at once. A device that behaves on a lab bench with clean power can fail in all four. This is the checklist we work from.
Treat brownouts as normal
Before power fails, the supply often sags. A microcontroller that keeps running on a sagging supply can corrupt a flash write or behave erratically. The ESP32's brownout detector resets the chip below a set threshold. Keep it enabled; ESP-IDF turns it on by default.
Make every write survive a cut
Assume power can disappear in the middle of any flash write.
- Keep settings in NVS, which ESP-IDF designs to tolerate power loss during writes.
- Write logs to a file system built for power loss, such as LittleFS, rather than FAT.
- Write less often. Collect readings in RAM and flush them in batches.
Ride through short gaps
An inverter takes a moment to pick up the load, and even a short gap resets an unprepared device. A bulk capacitor or a supercapacitor on the DC side can carry a low-power device through a switch-over. A voltage-sense input on the supply lets the firmware save its state when the input starts to fall.
Expect the whole area to come back at once
When power returns to a neighbourhood, every device reboots in the same second and tries to join Wi-Fi and the broker together. Wait a random delay before the first connection, and use exponential backoff with jitter on retries, so your broker doesn't face a reconnect storm.
Recover without a visit
- Keep the task and interrupt watchdogs enabled, and feed them only from tasks that are doing real work.
- Use OTA with rollback, so an update cut short by a power failure leaves the previous firmware bootable. In ESP-IDF, a new image is marked valid only after it has run correctly.
- Read the reset reason at boot with
esp_reset_reason()and publish it, so field data tells brownouts apart from crashes.
Test it the way the field will
- Switch the supply off and on at random moments, including during flash writes and during an OTA update.
- Sag the supply slowly with an adjustable bench supply and watch what the device does on the way down.
- Restart a batch of devices together against your real broker.
A device that passes these on the bench is far less likely to need a site visit after the next outage.